EAVE PROTECTION
Eave protection shall be provided on shingle, shake or tile roofs, extending from the edge of the roof a minimum of 900 mm (36 in) up the roof slope to a line not less than 300 mm (12 in) inside the inner face of the exterior wall. Eave protection is not required over unheated garages, carports and porches, where the roof overhang exceeds 900 mm (36 in) measured along the roof slope from the edge of the roof to the inner face of the exterior wall, on roofs with slopes of 1 in 1.5 (8/12) or greater. Eave protection shall be laid beneath the starter strip and shall consist of, No. 15 asphalt-saturated felt laid in two plies lapped 480 mm and cemented together with lap cement or self-sealing composite membranes consisting of modified bituminous coated material.THIS IS THE MOST OVERLOOKED DETAIL IN ROOFING QUOTATIONS! Even some of the most “reputable” contractors in Windsor Essex will tell their customers this is not required to save costs and keep their price attractive. Many contractors will recommend standard No. 15 felt paper for 3’ and a bare deck to the peak. This is a BIG RED FLAG.